Standard Power Rating, kVA (kW) |
27.5
(22) |
33
(26) |
38.5
(31) |
44
(35) |
49.5
(40) |
55
(44) |
69
(55) |
91
(73) |
110
(88) |
137.5
(110) |
|
Prime Power Rating,
kVA (kW) |
25
(20) |
30
(24) |
35
(28) |
40
(32) |
45
(36) |
50
(40) |
62.5
(50) |
82.5
(66) |
100
(80) |
125
(100) |
|
Engine Model |
497SPTC
78 |
497SPTC
77 |
497SPTC
76 |
497TC
76 |
497TC
75 |
497TC
75 |
497TC
74 |
697TC
51 |
697TC
52 |
697TC
10 |
|
Load Amperes
@ 415V |
35 |
42 |
49 |
56 |
63 |
70 |
87 |
115 |
139 |
174 |
|
Engine Power
Bhp |
40.2 |
48.2 |
56.3 |
56.3 |
56.3 |
75.7 |
90 |
120 |
125.3 |
156 |
|
FIP
Governing Type |
Inline Pump (MICO Bosch)
Mech-A1 Governing |
Emission Norms |
CPCB II |
Power Factor |
0.8 |
ALTERNATOR SPECIFICATIONS |
Make |
Stamford |
Type(PF) |
Brushless (0.8) |
Rpm / Frequency,
hz |
1500 / 50 |
Voltage Regulation |
230/415 I 100/230 |
Enclosure Type |
IP 23 |
Class of Insulation |
H Class |
CONTROL PANEL |
Standard Manual Control Panel with Digital Engine Safety & Measurement Controller (AMF Panel – as per specific requirement / application)
Modes available – Manual / Automatic |
ACOUSTICS SPECIFICATIONS |
Acoustics Enclosure
(Canopy) |
Built out of TATA Steel – CRC sheet with CNC Machines for precision & 7 tank treated & powder coated with Akzo Nobel Paint. |
Foam Thickness on Doors (mm) |
|
Density of foam for sound insulation |
|
Starting System |
12V DC |
Battery (Ah) |
|
Noise level, dB |
75dBA @ 1 meter distance (as per the stringent testing guidelines of Central Pollution Control Board, India) |
Exhaust Silencer |
Inside silencer upto 62.5 Kva |
|
|
Canopy size
(LxBxH) in mm |
2350 x 1030 x 1425 |
2700 x 1100 x 1550 |
3200 x 1200 x 1800 |
|
Weight, kg |
850 |
900 |
950 |
980 |
1000 |
1100 |
1250 |
1600 |
1700 |
1750 |
|
Fuel Tank capacity (Ltr ) |
|
Standby Power: Standby power is defined as the maximum power available during a variable electric power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 500 hours of operation per year under average of 70% load. Overloading is not permissible |
Prime Power: Prime power is defined as being the maximum power which the generator set is capable of delivering continuously whilst supplying a constant electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with maintenance intervals and procedures being carried out as prescribed by the manufacturer. |